| NOTE: | Waiting for the heater to cool will prolong the life of the heater. |
|---|
| The dehydrator operates on 115 VAC. This voltage can kill or injure. When performing repairs, lock and tag out the unit. Only qualified, authorized personnel should attempt electrical maintenance on energized equipment. |
| NOTE: | The sensing bulb is located in a well, isolated from the 450 psig in the air system. |
|---|
| NOTE: | The terminals inside the controller are marked, from left to right: switch 1 NO, NC, common, switch 2 NO, NC, common. The incoming electrical leads are marked 22, 23, and 24. |
|---|
| CAUTION: | Avoid bending or coiling the capillary tube tighter than 1/2" radius. Exercise caution when making bends near the capillary ends. |
|---|
| CAUTION: | Exceeding 10 scfm (0.28 m3/min) air flow rate will cause the unit to deliver wet air. |
|---|