The Model 5295 Condenser-Filter Air Dehydrator provides clean, dry air with the maximum of reliability and minimum of maintenance expense. Originally designed for use aboard the DDG-51 class AEGIS destroyers, it has been installed on other classes, including the CVN 65, DD 963, LHA 1, LHD 1, LSD 49, LCC 19, AOE 6, AS 39 and T AE-26 classes. Using only ship's chilled water to condense water vapor from the compressed air, the Model 5295 is ideal for replacing CFC-based refrigerated dehydrators from shipboard service.
Model 5295s have been specified for recent new construction on the LHD 1 and LSD 49 classes. Many Model 5295s have already been installed as retrofits on other classes pursuant to formal SARs: AGF 3 5086D, LSD 36 551D, LSD 41 1241D, AOE 1 803D, and LPD 4 1183D.
Operation of the Model 5295 is completely automatic. Simple, robust design and low maintenance requirements ensure minimum life cycle cost of ownership. Configurations providing different fittings and instrumentation suites are available to satisfy various class requirements.
|
Built to Military Specification MIL-D-24693, dated 23 November 1987, “Dehydrator, Condenser-Filter, Low-Pressure Air,” Class 2, 200 scfm. Fully qualifi ed to Military Specification MIL-S-901C, High Impact Shock (Grade A), and Military Standard MIL-STD-167, Vibration (Environmental) Shipboard.
| Mark I, IA | Mark II | Mark III | Mark IV | Mark V | Mark VI | |
|---|---|---|---|---|---|---|
| Customer | BIW, Ingalls | Avondale | Ingalls | Ingalls | NASSCO | Norfolk |
| Application | DDG 54 & up |
LSD 49, AE 26, LPD 17 |
DD 969 | LHD 5, LHD 8 | AOE 10 Class | LHA 2, LCC 20, AGF 3, LHD-1 |
| Technical Manual | S9514-DJ- MMA-010 |
S9514-DJ- MMA-010 |
none | S9514-E7- MMM-010 |
S9551-CB- MMA-010 |
S9514-FD- MMD-010 |
| Mark I, IA | Mark II | Mark III | Mark IV | Mark V | Mark VI | |
|---|---|---|---|---|---|---|
| MIL-F-1183 bronze nuts & tailpieces provided with unit to attach to ship’s piping and mate iwth dehydrator air inlet and outlet | X | X | X | X | ||
| Stainless equivalent of MIL-F-1183 air inlet and outlet fittings | X | |||||
| Socket-welded stainless steel fittings in place of MIL-F-1183 fittings | X | |||||
| Water inlet and outlet pressure gauges | X | X | X | X | ||
| High-outlet-air-temperature alarm time delay override switch | X | X | X | X | ||
| Remote alarm connection sense normally-open | X | X | X | X | X | |
| Remote alarm connection sense normally-closed | X | |||||
| Built in accordance with MIL-D-24693 | X | X | X | X | X | |
| Built in accordance with MIL-D-24693 and Amendment A | X | |||||