The Model 4870 Low-Pressure Air Control Panel is designed to control the pressure and to monitor the flow rate and moisture content of clean, dry compressed air to electronic equipment and components. The panel is designed for either automatic or manual operation.
Air pressure is regulated by two (or, for the Type III, one) pressure regulators. Flow rate of air being delivered to the using equipment is measured by a direct-reading float-in-tube flowmeter. A humidity alarm system monitors the moisture content of the air passing through the panel and energizes a local alarm if the moisture level rises above a preset value of -15° F dew point at 80 psig.
Configurations other than those shown here may be special-ordered.
| U.S. Navy Type and Class: | IA | IB | IC | IIA | IIB | III |
| Inlet Pressure: | -- 80 - 150 psig -- | |||||
| Intermediate Pressure, psig (± 2 psi) | 50 | 50 | 50 | 70 | 70 | 75 |
| Outlet Pressure, psig (± 1/4 psi) | 0 - 10 | 10 - 20 | 20 - 30 | 25 - 40 | 40 - 60 | n/a |
| Flow, scfm: | 0 - 10 | 0 - 10 | 0 - 10 | 0 - 10 | 0 - 10 | 0 - 15 |
| Dew Point Alarm: | -- -15° F @ 80 psig -- | |||||
| Relief Valve Setting: | -- Outlet + 3 to 5 psi -- |
-- Outlet + 10% psi -- |
||||
Last updated: 04/18/2008
|